Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Laryngoscope ; 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656740

RESUMEN

OBJECTIVES: Research samples that are representative of patient populations are needed to ensure the generalizability of study findings. The primary aim was to assess the efficacy of a study design and recruitment strategy in obtaining a participant sample that was representative of the broader cochlear implant (CI) patient population at the CI center. A secondary aim was to review whether the CI recipient population was representative of the state population. METHODS: Demographic variables were compared for a research participant sample (n = 79) and the CI patient population (n = 338). The participant sample was recruited from the CI patient population. The study design included visits that were at the same location and frequency as the recommended clinical follow-up intervals. The demographics for the combined group (participant sample and patient population) were then compared to the reported demographics for the population in North Carolina. RESULTS: There were no significant differences between the participant sample and patient population for biological sex, age at implantation, racial distribution, socioeconomic position, degree of urbanization, or drive time to the CI center (p ≥ 0.086). The combined CI recipient population was significantly different from the North Carolina population for the distributions of race, ethnicity, and degree of urbanization (p < 0.001). CONCLUSION: The study design and recruitment strategy allowed for recruitment of a participant sample that was representative of the CI patient population. Disparities in access to cochlear implantation persist, as supported by the significant differences in the combined CI recipient population and the population for our state. LEVEL OF EVIDENCE: 3 Laryngoscope, 2024.

2.
Laryngoscope ; 134(4): 1868-1873, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37767794

RESUMEN

OBJECTIVE: Determine variables that influence post-activation performance for cochlear implant (CI) recipients who lost low-frequency acoustic hearing. METHODS: A retrospective review evaluated CNC word recognition for adults with normal to moderately severe low-frequency hearing (preoperative unaided thresholds of ≤70 dB HL at 250 Hz) who were implanted between 2012 and 2021 at a tertiary academic center, lost functional acoustic hearing, and were fit with a CI-alone device. Performance scores were queried from the 1, 3, 6, 12, and 24-month post-activation visits. A linear mixed model evaluated the effects of age at implantation, array length (long vs. mid/short), and preoperative low-frequency hearing (normal to mild, moderate, and moderately severe) on speech recognition with a CI alone. RESULTS: 113 patients met the inclusion criteria. There was a significant main effect of interval (p < 0.001), indicating improved word recognition post-activation despite loss of residual hearing. There were significant main effects of age (p = 0.029) and array length (p = 0.038), with no effect of preoperative low-frequency hearing (p = 0.171). There was a significant 2-way interaction between age and array length (p = 0.018), indicating that older adults with mid/short arrays performed more poorly than younger adults with long lateral wall arrays when functional acoustic hearing was lost. CONCLUSION: CI recipients with preoperative functional low-frequency hearing experience a significant improvement in speech recognition with a CI alone as compared to preoperative performance-despite the loss of low-frequency hearing. Age and electrode array length may play a role in post-activation performance. These data have implications for the preoperative counseling and device selection for hearing preservation candidates. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:1868-1873, 2024.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Anciano , Percepción del Habla/fisiología , Audición , Pruebas Auditivas , Resultado del Tratamiento
3.
Laryngoscope ; 134(2): 919-925, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37466238

RESUMEN

OBJECTIVE: To assess the perceived benefit of cochlear implant (CI) use for children with unilateral hearing loss (UHL) and evaluate whether perceived abilities are associated with performance on measures of speech recognition and spatial hearing. METHOD: Nineteen children with moderate-to-profound UHL underwent cochlear implantation. The Speech Spatial and Qualities of Hearing Questionnaire modified for children (SSQ-C) were completed by parental proxy pre-operatively and at 3, 6, 9, 12, 18, and 24 months post-activation. Linear mixed models evaluated perceived benefits over the study period. Pearson correlations assessed the association between subjective report and performance on measures of word recognition with the CI alone and spatial hearing (speech recognition in spatially-separated noise and sound source localization) in the combined condition (CI plus contralateral ear). RESULTS: For the SSQ-C, parents reported significant improvements with CI use as compared to pre-operative perceptions (p < 0.001); improved perceptions were either maintained or continued to improve over the 2-year post-activation period. Perceived benefit did not significantly correlate with word recognition with the CI alone or spatial hearing outcomes in the combined condition. CONCLUSION: Families of children with UHL observed benefits of CI use early after cochlear implantation that was maintained with long-term device use. Responses to subjective measures may broaden our understanding of the experiences of pediatric CI users with UHL in addition to outcomes on typical measures of CI performance. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:919-925, 2024.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Localización de Sonidos , Percepción del Habla , Humanos , Niño , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Percepción del Habla/fisiología , Audición , Localización de Sonidos/fisiología , Resultado del Tratamiento
4.
Otol Neurotol ; 44(10): 1004-1010, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37758328

RESUMEN

OBJECTIVES: To investigate the incidence of electrode contacts within the functional acoustic hearing region in cochlear implant (CI) recipients and to assess its influence on speech recognition for electric-acoustic stimulation (EAS) users. STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. PATIENTS: One hundred five CI recipients with functional acoustic hearing preservation (≤80 dB HL at 250 Hz). INTERVENTIONS: Cochlear implantation with a 24-, 28-, or 31.5-mm lateral wall electrode array. MAIN OUTCOME MEASURES: Angular insertion depth (AID) of individual contacts was determined from imaging. Unaided acoustic thresholds and AID were used to calculate the proximity of contacts to the functional acoustic hearing region. The association between proximity values and speech recognition in quiet and noise for EAS users at 6 months postactivation was reviewed. RESULTS: Sixty percent of cases had one or more contacts within the functional acoustic hearing region. Proximity was not significantly associated with speech recognition in quiet. Better performance in noise was observed for cases with close correspondence between the most apical contact and the upper edge of residual hearing, with poorer results for increasing proximity values in either the basal or apical direction ( r14 = 0.48, p = 0.043; r18 = -0.41, p = 0.045, respectively). CONCLUSION: There was a high incidence of electrode contacts within the functional acoustic hearing region, which is not accounted for with default mapping procedures. The variability in outcomes across EAS users with default maps may be due in part to electric-on-acoustic interference, electric frequency-to-place mismatch, and/or failure to stimulate regions intermediate between the most apical electrode contact and the functional acoustic hearing region.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Implantes Cocleares/efectos adversos , Implantación Coclear/métodos , Estimulación Acústica/métodos , Percepción del Habla/fisiología , Incidencia , Audición , Estimulación Eléctrica/métodos
5.
Audiol Neurootol ; 28(6): 478-487, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37482054

RESUMEN

INTRODUCTION: Cochlear implant (CI) and electric-acoustic stimulation (EAS) users may experience better performance with maps that align the electric filter frequencies to the cochlear place frequencies, known as place-based maps, than with maps that present spectrally shifted information. Individual place-based mapping procedures differ in the frequency content that is aligned to cochlear tonotopicity versus discarded or spectrally shifted. The performance benefit with different place-based maps may vary due to individual differences in angular insertion depth (AID) of the electrode array and whether functional acoustic low-frequency information is available in the implanted ear. The present study compared masked speech recognition with two types of place-based maps as a function of AID and presence of acoustic low-frequency information. METHODS: Sixty adults with normal hearing listened acutely to CI or EAS simulations of two types of place-based maps for one of three cases of electrode arrays at shallow AIDs. The strict place-based (Strict-PB) map aligned the low- and mid-frequency information to cochlear tonotopicity and discarded information below the frequency associated with the most apical electrode contact. The alternative place-based map (LFshift-PB) aligned the mid-frequency information to cochlear tonotopicity and provided more of the speech spectrum by compressing low-frequency information on the apical electrode contacts (i.e., <1 kHz). Three actual cases of a 12-channel, 24-mm electrode array were simulated by assigning the carrier frequency for an individual channel as the cochlear place frequency of the associated electrode contact. The AID and cochlear place frequency for the most apical electrode contact were 460° and 498 Hz for case 1, 389° and 728 Hz for case 2, and 335° and 987 Hz for case 3, respectively. RESULTS: Generally, better performance was observed with the Strict-PB maps for cases 1 and 2, where mismatches were 2-4 octaves for the most apical channel with the LFshift-PB map. Similar performance was observed between maps for case 3. For the CI simulations, performance with the Strict-PB map declined with decreases in AID, while performance with the LFshift-PB map remained stable across cases. For the EAS simulations, performance with the Strict-PB map remained stable across cases, while performance with the LFshift-PB map improved with decreases in AID. CONCLUSIONS: Listeners demonstrated differences with the Strict-PB versus LFshift-PB maps as a function of AID and whether acoustic low-frequency information was available (CI vs. EAS). These data support the use of the Strict-PB mapping procedure for AIDs ≥335°, though further study including time for acclimatization in CI and EAS users is warranted.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Humanos , Implantación Coclear/métodos , Cóclea , Estimulación Acústica , Percepción del Habla/fisiología , Acústica , Estimulación Eléctrica
6.
Front Hum Neurosci ; 17: 1141065, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37250696

RESUMEN

Introduction: Candidacy criteria for cochlear implantation in the United States has expanded to include children with single-sided deafness (SSD) who are at least 5 years of age. Pediatric cochlear implant (CI) users with SSD experience improved speech recognition with increased daily device use. There are few studies that report the hearing hour percentage (HHP) or the incidence of non-use for pediatric CI recipients with SSD. The aim of this study was to investigate factors that impact outcomes in children with SSD who use CIs. A secondary aim was to identify factors that impact daily device use in this population. Methods: A clinical database query revealed 97 pediatric CI recipients with SSD who underwent implantation between 2014 and 2022 and had records of datalogs. The clinical test battery included speech recognition assessment for CNC words with the CI-alone and BKB-SIN with the CI plus the normal-hearing ear (combined condition). The target and masker for the BKB-SIN were presented in collocated and spatially separated conditions to evaluate spatial release from masking (SRM). Linear mixed-effects models evaluated the influence of time since activation, duration of deafness, HHP, and age at activation on performance (CNC and SRM). A separate linear mixed-effects model evaluated the main effects of age at testing, time since activation, duration of deafness, and onset of deafness (stable, progressive, or sudden) on HHP. Results: Longer time since activation, shorter duration of deafness, and higher HHP were significantly correlated with better CNC word scores. Younger age at device activation was not found to be a significant predictor of CNC outcomes. There was a significant relationship between HHP and SRM, with children who had higher HHP experiencing greater SRM. There was a significant negative correlation between time since activation and age at test with HHP. Children with sudden hearing loss had a higher HHP than children with progressive and congenital hearing losses. Conclusion: The present data presented here do not support a cut-off age or duration of deafness for pediatric cochlear implantation in cases of SSD. Instead, they expand on our understanding of the benefits of CI use in this population by reviewing the factors that influence outcomes in this growing patient population. Higher HHP, or greater percentage of time spent each day using bilateral input, was associated with better outcomes in the CI-alone and in the combined condition. Younger children and those within the first months of use had higher HHP. Clinicians should discuss these factors and how they may influence CI outcomes with potential candidates with SSD and their families. Ongoing work is investigating the long-term outcomes in this patient population, including whether increasing HHP after a period of limited CI use results in improved outcomes.

7.
Laryngoscope ; 133(12): 3540-3547, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37078508

RESUMEN

OBJECTIVE: Comparison of acute speech recognition for cochlear implant (CI) alone and electric-acoustic stimulation (EAS) users listening with default maps or place-based maps using either a spiral ganglion (SG) or a new Synchrotron Radiation-Artificial Intelligence (SR-AI) frequency-to-place function. METHODS: Thirteen adult CI-alone or EAS users completed a task of speech recognition at initial device activation with maps that differed in the electric filter frequency assignments. The three map conditions were: (1) maps with the default filter settings (default map), (2) place-based maps with filters aligned to cochlear SG tonotopicity using the SG function (SG place-based map), and (3) place-based maps with filters aligned to cochlear Organ of Corti (OC) tonotopicity using the SR-AI function (SR-AI place-based map). Speech recognition was evaluated using a vowel recognition task. Performance was scored as the percent correct for formant 1 recognition due to the rationale that the maps would deviate the most in the estimated cochlear place frequency for low frequencies. RESULTS: On average, participants had better performance with the OC SR-AI place-based map as compared to the SG place-based map and the default map. A larger performance benefit was observed for EAS users than for CI-alone users. CONCLUSION: These pilot data suggest that EAS and CI-alone users may experience better performance with a patient-centered mapping approach that accounts for the variability in cochlear morphology (OC SR-AI frequency-to-place function) in the individualization of the electric filter frequencies (place-based mapping procedure). LEVEL OF EVIDENCE: 3 Laryngoscope, 133:3540-3547, 2023.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Humanos , Inteligencia Artificial , Cóclea/anatomía & histología , Estimulación Acústica/métodos
8.
Ear Hear ; 44(5): 955-968, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36879386

RESUMEN

OBJECTIVES: Children with severe-to-profound unilateral hearing loss, including cases of single-sided deafness (SSD), lack access to binaural cues that support spatial hearing, such as recognizing speech in complex multisource environments and sound source localization. Listening in a monaural condition negatively impacts communication, learning, and quality of life for children with SSD. Cochlear implant (CI) use may restore binaural hearing abilities and improve outcomes as compared to alternative treatments or no treatment. This study investigated performance over 24 months of CI use in young children with SSD as compared to the better hearing ear alone and to children with bilateral normal hearing (NH). DESIGN: Eighteen children with SSD who received a CI between the ages of 3.5 and 6.5 years as part of a prospective clinical trial completed assessments of word recognition in quiet, masked sentence recognition, and sound source localization at regular intervals out to 24-month postactivation. Eighteen peers with bilateral NH, matched by age at the group level, completed the same test battery. Performance at 24-month postactivation for the SSD group was compared to the performance of the NH group. RESULTS: Children with SSD have significantly poorer speech recognition in quiet, masked sentence recognition, and localization both with and without the use of the CI than their peers with NH. The SSD group experienced significant benefits with the CI+NH versus the NH ear alone on measures of isolated word recognition, masked sentence recognition, and localization. These benefits were realized within the first 3 months of use and were maintained through the 24-month postactivation interval. CONCLUSIONS: Young children with SSD who use a CI experience significant isolated word recognition and bilateral spatial hearing benefits, although their performance remains poorer than their peers with NH.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Localización de Sonidos , Percepción del Habla , Humanos , Niño , Preescolar , Lactante , Pérdida Auditiva Unilateral/rehabilitación , Calidad de Vida , Estudios Prospectivos , Audición
9.
Laryngoscope Investig Otolaryngol ; 8(1): 296-302, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36846426

RESUMEN

Objectives: Access to cochlear implantation may be negatively influenced by extended travel time to a cochlear implant (CI) center or lower socioeconomic status (SES) for the individual. There is a critical need to understand the influence of these variables on patient appointment attendance for candidacy evaluations, and CI recipients' adherence to post-activation follow-up recommendations that support optimal outcomes. Methods: A retrospective chart review of adult patients referred to a CI center in North Carolina for initial cochlear implantation candidacy evaluation between April 2017 and July 2019 was conducted. Demographic and audiologic data were collected for each patient. Travel time was determined using geocoding. SES was proxied using ZCTA-level Social Deprivation Index (SDI) information. Independent samples t tests compared variables between those who did and did not attend the candidacy evaluation. Pearson correlations assessed the association of these variables and the duration of time between initial CI activation and return for first follow-up visit. Results: Three hundred and ninety patients met the inclusion criteria. There was a statistically significant difference between SDI of those who attended their candidacy evaluation versus those who did not. Age at referral or travel time did not show statistical significance between these two groups. There was no significant correlation with age at referral, travel time, or SDI with the duration of time (days) between initial activation and the 1-month follow-up. Conclusions: Our findings suggest that SES may influence a patient's ability to attend a cochlear implantation candidacy evaluation appointment and may further impact the decision to pursue cochlear implantation.Level of evidence: 4 - Case Series.

10.
Am J Audiol ; 32(1): 251-260, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36800505

RESUMEN

PURPOSE: Cochlear implant (CI) recipients with hearing preservation experience significant improvements in speech recognition with electric-acoustic stimulation (EAS) as compared to with a CI alone, although outcomes across EAS users vary. The individual differences in performance may be due in part to default mapping procedures, which result in electric frequency-to-place mismatches for the majority of EAS users. This study assessed the influence of electric mismatches on the early speech recognition for EAS users. METHOD: Twenty-one participants were randomized at EAS activation to listen exclusively with a default or place-based map. For both groups, the unaided thresholds determined the acoustic cutoff frequency (i.e., > 65 dB HL). For default maps, the electric filter frequencies were assigned to avoid spectral gaps in frequency information but created varying magnitudes of mismatches. For place-based maps, the electric filter frequencies were assigned to avoid frequency-to-place mismatches. Recognition of consonant-nucleus-consonant words and vowels was assessed at activation and 1, 3, and 6 months postactivation. RESULTS: For participants with default maps, electric mismatch at 1500 Hz ranged from 2 to -12.0 semitones (Mdn = -5 semitones). Poorer performance was observed for those with larger magnitudes of electric mismatch. This effect was observed through 6 months of EAS listening experience. CONCLUSIONS: The present sample of EAS users experienced better initial performance when electric mismatches were small or eliminated. These data suggest the utility of methods that reduce electric mismatches, such as place-based mapping procedures. Investigation is ongoing to determine whether these differences persist with long-term EAS use. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.22096523.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Estimulación Acústica/métodos , Percepción del Habla/fisiología , Implantación Coclear/métodos , Audición
11.
Otol Neurotol ; 44(4): 297-309, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36791341

RESUMEN

OBJECTIVE: To assess spatial hearing, tinnitus, and quality-of-life outcomes in adults with single-sided deafness (SSD) who underwent cochlear implantation. DATABASES REVIEWED: PubMed, MEDLINE, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus databases were searched from January 2008 to September 2021 following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. METHODS: Studies reporting spatial hearing, tinnitus, and quality-of-life outcomes in adult cochlear implant (CI) recipients (≥18 yr old) with SSD were evaluated. Study characteristics, demographic data, spatial hearing (speech recognition in noise, sound source localization), tinnitus (severity, loudness), and quality-of-life outcomes were collected. RESULTS: From an initial search of 1,147 articles, 36 studies that evaluated CI use in 796 unique adults with SSD (51.3 ± 12.4 yr of age at time of implantation) were included. The mean duration of deafness was 6.2 ± 9.6 years. There was evidence of improvement for speech recognition in noise using different target-to-masker spatial configurations, with the largest benefit observed for target-to-masker configurations assessing head shadow (mean, 1.87-6.2 dB signal-to-noise ratio). Sound source localization, quantified as root-mean-squared error, improved with CI use (mean difference [MD], -25.3 degrees; 95% confidence interval [95% CI], -35.9 to -14.6 degrees; p < 0.001). Also, CI users reported a significant reduction in tinnitus severity as measured with the Tinnitus Handicap Inventory (MD, -29.97; 95% CI, -43.9 to -16.1; p < 0.001) and an improvement in spatial hearing abilities as measured with the Spatial, Speech, and Qualities of Hearing questionnaire (MD, 2.3; 95% CI, 1.7 to 2.8; p < 0.001). CONCLUSIONS: Cochlear implantation and CI use consistently offer improvements in speech recognition in noise, sound source localization, tinnitus, and perceived quality of life in adults with SSD.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Pérdida Auditiva Unilateral/psicología , Pérdida Auditiva Unilateral/cirugía , Humanos , Adulto , Calidad de Vida , Localización de Sonidos , Percepción del Habla , Acúfeno
12.
Laryngoscope ; 133(10): 2792-2797, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36757052

RESUMEN

OBJECTIVES: Assess the long-term patterns of perceived tinnitus severity and subjective benefit for adult cochlear implant (CI) users with asymmetric or unilateral hearing loss (AHL or UHL). METHODS: Forty adults underwent cochlear implantation as part of a prospective clinical trial assessing the outcomes of CI use in cases of AHL (n = 20) and UHL (n = 20). Subjective measures included the Tinnitus Handicap Inventory (THI), the Speech, Spatial, & Qualities of Hearing Scale (SSQ), and the Abbreviated Profile of Hearing Aid Benefit (APHAB). Responses were obtained preoperatively and at routine intervals out to 5 years post-activation. RESULTS: For subjective benefit, participants with AHL and UHL reported a significant improvement as compared to preoperative abilities, which was maintained with long-term CI use. For perceived tinnitus severity, participants with AHL and UHL reported a significant reduction with CI use as compared to preoperative perceptions. The perceived tinnitus severity significantly differed for the AHL and UHL cohorts over time. This pattern of results is likely influenced by the worse perceived severity levels for the UHL cohort preoperatively and the fluctuating perceived severity levels for some participants in the AHL cohort post-activation. CONCLUSION: Adults with AHL and UHL report an early, significant reduction in perceived tinnitus severity and improvement in quality of life with CI use that is generally maintained with long-term device use. Questionnaires such as the THI, SSQ, and APHAB may contribute to a more holistic assessment of the benefits of cochlear implantation in this population. LEVEL OF EVIDENCE: 2 Laryngoscope, 133:2792-2797, 2023.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Pérdida Auditiva , Percepción del Habla , Acúfeno , Adulto , Humanos , Implantación Coclear/métodos , Pérdida Auditiva/cirugía , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación , Estudios Prospectivos , Calidad de Vida , Percepción del Habla/fisiología , Acúfeno/cirugía , Resultado del Tratamiento
13.
Laryngoscope ; 133(6): 1480-1485, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36053850

RESUMEN

OBJECTIVE: To assess long-term binaural hearing abilities for cochlear implant (CI) users with unilateral hearing loss (UHL) or asymmetric hearing loss (AHL). METHODS: A prospective, longitudinal, repeated measures study was completed at a tertiary referral center evaluating adults with UHL or AHL undergoing cochlear implantation. Binaural hearing abilities were assessed with masked speech recognition tasks using AzBio sentences in a 10-talker masker. Performance was evaluated as the ability to benefit from spatial release from masking (SRM). SRM was calculated as the difference in scores when the masker was presented toward the CI-ear (SRMci ) or the contralateral ear (SRMcontra ) relative to the co-located condition (0°). Assessments were completed pre-operatively and at annual intervals out to 5 years post-activation. RESULTS: Twenty UHL and 19 AHL participants were included in the study. Linear Mixed Models showed significant main effects of interval and group for SRMcontra . There was a significant interaction between interval and group, with UHL participants reaching asymptotic performance early and AHL participants demonstrating continued growth in binaural abilities to 5 years post-activation. The improvement in SRM showed a significant positive correlation with contralateral unaided hearing thresholds (p = 0.050) as well as age at implantation (p = 0.031). CONCLUSIONS: CI recipients with UHL and AHL showed improved SRM with long-term device use. The time course of improvement varied by cohort, with the UHL cohort reaching asymptotic performance early and the AHL cohort continuing to improve beyond 1 year. Differences between cohorts could be driven by differences in age at implantation as well as contralateral unaided hearing thresholds. LEVEL OF EVIDENCE: 3 Laryngoscope, 133:1480-1485, 2023.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Pérdida Auditiva , Percepción del Habla , Adulto , Humanos , Estudios Prospectivos , Audición , Pérdida Auditiva/cirugía , Pérdida Auditiva Unilateral/cirugía , Pérdida Auditiva Unilateral/rehabilitación
14.
J Speech Lang Hear Res ; 65(9): 3539-3547, 2022 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-36001854

RESUMEN

PURPOSE: The U.S. Food and Drug Administration indications for cochlear implantation in children is currently 9 months of age and older for children with bilateral profound sensorineural hearing loss (SNHL). Studies have shown that earlier activation of a cochlear implant (CI) can lead to better spoken language outcomes. As auditory skills are a precursor to the development of spoken language, this study was developed to investigate the influence of age at CI activation on auditory skill acquisition in young children. A secondary aim was to describe the auditory skills of children implanted prior to 9 months of age as compared to children with older ages of activation. METHOD: Functional Listening Index (FLI) scores obtained during routine clinical visits were reviewed for 78 pediatric CI recipients with congenital bilateral profound hearing loss who were activated before 2 years of age. A linear mixed-effects model assessed the effect of age at CI activation on cumulative FLI scores over time. RESULTS: There was a significant interaction between age at activation and chronological age at the time of evaluation, indicating that children with earlier access to sound achieved a greater number of auditory skills than those with later CI activations when measured at the same chronological age. Children activated before the age of 9 months approximated scores expected of children with typical hearing, whereas children activated between 9 and 24 months of age did not. CONCLUSIONS: Younger age at CI activation is associated with increased auditory skills over time. Children who undergo cochlear implantation and CI activation before 9 months achieve more auditory skills by 4 years of age than children who are activated at later ages. These data suggest that reducing the approved age at cochlear implantation for children with congenital bilateral profound SNHL may support optimal auditory skill acquisition.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Sensorineural , Niño , Preescolar , Implantación Coclear/métodos , Sordera/rehabilitación , Sordera/cirugía , Pérdida Auditiva Bilateral/rehabilitación , Pérdida Auditiva Sensorineural/rehabilitación , Pérdida Auditiva Sensorineural/cirugía , Humanos , Lactante , Desarrollo del Lenguaje
15.
Ear Hear ; 43(6): 1605-1619, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35994570

RESUMEN

The indications for cochlear implantation have expanded to include individuals with profound sensorineural hearing loss in the impaired ear and normal hearing (NH) in the contralateral ear, known as single-sided deafness (SSD). There are additional considerations for the clinical assessment and management of adult cochlear implant candidates and recipients with SSD as compared to conventional cochlear implant candidates with bilateral moderate to profound sensorineural hearing loss. The present report reviews the current evidence relevant to the assessment and management of adults with SSD. A systematic review was also conducted on published studies that investigated outcomes of cochlear implant use on measures of speech recognition in quiet and noise, sound source localization, tinnitus perception, and quality of life for this patient population. Expert consensus and systematic review of the current literature were combined to provide guidance for the clinical assessment and management of adults with SSD.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Sensorineural , Pérdida Auditiva Unilateral , Localización de Sonidos , Percepción del Habla , Adulto , Humanos , Calidad de Vida , Pérdida Auditiva Sensorineural/cirugía , Sordera/rehabilitación , Pérdida Auditiva Unilateral/rehabilitación , Resultado del Tratamiento
16.
Curr Opin Otolaryngol Head Neck Surg ; 30(5): 303-308, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-36004791

RESUMEN

PURPOSE OF REVIEW: Children and adults with unilateral or asymmetric hearing loss (UHL/AHL) have poorer spatial hearing (e.g. speech understanding in complex maskers and localization) and quality of life compared with peers with normal hearing bilaterally. Patients with UHL/AHL experience limited benefits with contralateral-routing technologies (e.g. bone conduction, CROS hearing aid systems). Cochlear implantation allows for stimulation of the auditory pathway for the poorer hearing ear. The present study reviews the recent literature on outcomes of cochlear implant use for recipients with UHL/AHL. RECENT FINDINGS: Recent research corroborates previous investigations of the significant benefits on measures of spatial hearing, tinnitus severity and quality of life for adult cochlear implant recipients. These benefits are also observed in pediatric cochlear implant recipients, with an association of better outcomes with younger ages at implantation for congenital cases and shorter durations of UHL/AHL for acquired cases. In addition, randomized trials demonstrate better outcomes with cochlear implant use versus contralateral-routing technologies. SUMMARY: Cochlear implantation supports better spatial hearing and quality of life in children and adults with UHL/AHL as compared to alternative listening conditions. Current research supports the expansion of candidacy criteria and insurance coverage for cochlear implantation for patients with UHL/AHL to improve their binaural hearing.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral , Pérdida Auditiva , Percepción del Habla , Adulto , Niño , Humanos , Calidad de Vida , Resultado del Tratamiento
17.
Otol Neurotol ; 43(7): e726-e729, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35820072

RESUMEN

OBJECTIVES: Review the effectiveness of an alternative mapping procedure of a precurved electrode array in the internal auditory canal (IAC). DESIGN: A 7-year-old bilateral cochlear implant (CI) recipient of precurved arrays transferred to the study site and demonstrated no speech recognition with the left CI. Imaging revealed bilateral incomplete partition type III malformations. For the left CI, four contacts were observed in the basal cochlear turn and 18 contacts were coiled in the IAC. The family decided against revision surgery. Pitch ranking was completed to map the contacts in the IAC that were perceptually discrete and tonotopically organized. RESULTS: For the left CI, PB-K word recognition improved from no recognition to 32% after 1 month and to 52% after 3 months. In the bilateral CI condition, performance improved from 56 to 72% after 1 month and 80% after 3 months. CONCLUSION: A precurved array in the IAC creates difficult management decisions. Direct stimulation of the auditory nerve resulted in better monaural and bilateral speech recognition, likely due to better spectral representation of the speech signal. Individualizing the map using imaging and behavioral findings may improve performance for malpositioned arrays when revision surgery is not pursued.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Oído Interno , Percepción del Habla , Niño , Implantación Coclear/métodos , Nervio Coclear/fisiología , Oído Interno/diagnóstico por imagen , Oído Interno/cirugía , Humanos , Habla
18.
Am J Audiol ; 31(3): 757-763, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35877957

RESUMEN

PURPOSE: Cochlear implant (CI) recipients with normal or near normal hearing (NH) in the contralateral ear, referred to as single-sided deafness (SSD), experience significantly better speech recognition in noise with their CI than without it, although reported outcomes vary. One possible explanation for differences in outcomes across studies could be differences in the spatial configurations used to assess performance. This study compared speech recognition for different spatial configurations of the target and masker, with test materials used clinically. METHOD: Sixteen CI users with SSD completed tasks of masked speech recognition presented in five spatial configurations. The target speech was presented from the front speaker (0° azimuth). The masker was located either 90° or 45° toward the CI-ear or NH-ear or colocated with the target. Materials were the AzBio sentences in a 10-talker masker and the Bamford-Kowal-Bench Speech-in-Noise test (BKB-SIN; four-talker masker). Spatial release from masking (SRM) was computed as the benefit associated with spatial separation relative to the colocated condition. RESULTS: Performance was significantly better when the masker was separated toward the CI-ear as compared to colocated. No benefit was observed for spatial separations toward the NH-ear. The magnitude of SRM for spatial separations toward the CI-ear was similar for 45° and 90° when tested with the AzBio sentences, but a larger benefit was observed for 90° as compared to 45° for the BKB-SIN. CONCLUSIONS: Masked speech recognition in CI users with SSD varies as a function of the spatial configuration of the target and masker. Results supported an expansion of the clinical test battery at the study site to assess binaural hearing abilities for CI candidates and recipients with SSD. The revised test battery presents the target from the front speaker and the masker colocated with the target, 90° toward the CI-ear, or 90° toward the NH-ear.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Percepción del Habla , Implantación Coclear/métodos , Humanos , Habla
19.
Am J Audiol ; 31(2): 322-337, 2022 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-35394798

RESUMEN

PURPOSE: Cochlear implant (CI) recipients demonstrate variable speech recognition when listening with a CI-alone or electric-acoustic stimulation (EAS) device, which may be due in part to electric frequency-to-place mismatches created by the default mapping procedures. Performance may be improved if the filter frequencies are aligned with the cochlear place frequencies, known as place-based mapping. Performance with default maps versus an experimental place-based map was compared for participants with normal hearing when listening to CI-alone or EAS simulations to observe potential outcomes prior to initiating an investigation with CI recipients. METHOD: A noise vocoder simulated CI-alone and EAS devices, mapped with default or place-based procedures. The simulations were based on an actual 24-mm electrode array recipient, whose insertion angles for each electrode contact were used to estimate the respective cochlear place frequency. The default maps used the filter frequencies assigned by the clinical software. The filter frequencies for the place-based maps aligned with the cochlear place frequencies for individual contacts in the low- to mid-frequency cochlear region. For the EAS simulations, low-frequency acoustic information was filtered to simulate aided low-frequency audibility. Performance was evaluated for the AzBio sentences presented in a 10-talker masker at +5 dB signal-to-noise ratio (SNR), +10 dB SNR, and asymptote. RESULTS: Performance was better with the place-based maps as compared with the default maps for both CI-alone and EAS simulations. For instance, median performance at +10 dB SNR for the CI-alone simulation was 57% correct for the place-based map and 20% for the default map. For the EAS simulation, those values were 59% and 37% correct. Adding acoustic low-frequency information resulted in a similar benefit for both maps. CONCLUSIONS: Reducing frequency-to-place mismatches, such as with the experimental place-based mapping procedure, produces a greater benefit in speech recognition than maximizing bandwidth for CI-alone and EAS simulations. Ongoing work is evaluating the initial and long-term performance benefits in CI-alone and EAS users. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.19529053.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Estimulación Acústica , Acústica , Humanos
20.
Audiol Neurootol ; 27(6): 437-448, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35439753

RESUMEN

INTRODUCTION: Cochlear implant (CI) recipients with normal hearing (NH) in the contralateral ear experience a significant improvement in sound source localization when listening with the CI in combination with their NH-ear (CI + NH) as compared to with the NH-ear alone. The improvement in localization is primarily due to sensitivity to interaural level differences (ILDs). Sensitivity to interaural timing differences (ITDs) may be limited by auditory aging, frequency-to-place mismatches, the signal coding strategy, and duration of CI use. The present report assessed the sensitivity of ILD and ITD cues in CI + NH listeners who were recipients of long electrode arrays that provide minimal frequency-to-place mismatches and were mapped with a coding strategy that presents fine structure cues on apical channels. METHODS: Sensitivity to ILDs and ITDs for localization was assessed using broadband noise (BBN), as well as high-pass (HP) and low-pass (LP) filtered noise for adult CI + NH listeners. Stimuli were 200-ms noise bursts presented from 11 speakers spaced evenly over an 180° arc. Performance was quantified in root-mean-squared error and response patterns were analyzed to evaluate the consistency, accuracy, and side bias of the responses. Fifteen listeners completed the task at the 2-year post-activation visit; seven listeners repeated the task at a later annual visit. RESULTS: Performance at the 2-year visit was best with the BBN and HP stimuli and poorer with the LP stimulus. Responses to the BBN and HP stimuli were significantly correlated, consistent with the idea that CI + NH listeners primarily use ILD cues for localization. For the LP stimulus, some listeners responded consistently and accurately and with limited side bias, which may indicate sensitivity to ITD cues. Two of the 7 listeners who repeated the task at a later annual visit experienced a significant improvement in performance with the LP stimulus, which may indicate that sensitivity to ITD cues may improve with long-term CI use. CONCLUSIONS: CI recipients with a NH-ear primarily use ILD cues for sound source localization, though some may use ITD cues as well. Sensitivity to ITD cues may improve with long-term CI listening experience.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Localización de Sonidos , Estimulación Acústica , Localización de Sonidos/fisiología , Audición
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...